  • Product Description
    • Commodity name: Winner Pro 10KVA/15KVA/20KVA/ Galleon 30KVA

    Model

    3C10KS3C15KS3C20KS3C30KS

    Phase

    three inputs, one output

    Capacity

    10000VA / 8000W15000VA / 12000W20000VA / 16000W30000VA / 24000W

    Input

     

    Rated voltage

    3 x 400 VAC (3Ph+N)

    Voltage range

    190-520 VAC (3-phase) at 50% load
    305-520 VAC (3-phase) at 100% load
    Frequency range46~54 Hz or 56~64Hz
    Output 

    Rated voltage

    208/220/230/240VAC

    Output accuracy (battery mode)

    ± 1%

    Frequency range (synchronization range)46~54 Hz for 50Hz systems / 56~64 Hz for 60Hz systems
    Frequency range (battery mode)50 Hz ± 0.2 Hz 或 60 Hz ± 0.2 Hz
    Crest factor of current3:1 ( max )
    THDV≦ 1% THD (linear load); ≦ 3% THD (non-linear load)
    Convert timeSwitch from mains power mode to battery modenone
    Inversion to bypassnone
    Waveform (battery mode)pure sine wave
    efficiency 
    Mains mode91%93%91%
    Battery Mode91%87%88%
    battery 
    standard machineBattery Type12V/9Ah 
    quantitySection 16Section 20Section 16Section 20Section 16Section 20 
    Standard charging timeCharged to 90% in 9 hours
    Maximum charging currentPreset 1A, adjustable 1A/2A/4A
    charging voltage218.4 VDC ± 1%

    273 VDC ± 

    1%

    218.4 VDC ± 

    1%

    273 VDC ± 1%

    218.4 VDC ±

     1%

    273 VDC ± 1% 
    Long-lasting machineBattery TypeIt depends on the applicant
    quantitySection 16Section 20Section 16Section 20Section 16 Section 20Section 16
    Maximum charging currentPre-set 4A, 1A/2A/4A (adjustable)12A
    charging voltage218.4 VDC ± 1%

    273 VDC ± 

    1%

    218.4 VDC ± 1%

    273 VDC ± 

    1%

    218.4 VDC ± 1%

    273 VDC ± 

    1%

    218.4 VDC ± 1%
    Display guide 
    LCD displaySystem status, load size, battery capacity, mains mode, battery mode, bypass mode, input/output voltage, fault indication
    Warning sound 
    Battery ModeIt rings once every 4 seconds
    Low batteryIt rings once every 1 seconds
    overloadIt rings once every 0.5 seconds
    faultycontinuous ringing
    Physical properties 
    standard machine D x W x H (mm) 442 x 190 x 688560×250 ×688575 x 250 x 688 
    Net weight (kg)667667787485 
    Long-lasting machine D x W x H (mm) 442 x 190 x 318560×250×580560×250×580815×250×826
    Net weight (kg)17253064
    Usage environment 
    temperature and humidityRelative humidity: 0-95% and temperature: 0-40°C (non-condensing)
    noiseless than 60dB @1 meter
    control management 
    Intelligent RS-232 / USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, and MAC
    Optional SNMPPower management for SNMP manager and web browser

Product inquiry